05). The sera of all non-symptomatic individuals (non-exposed individuals and claw trimmers) that were used as AZD8931 mouse negative controls showed no specific IgE antibodies against cattle
allergen with the Hycor test or the Phadia test. Detection of cattle-related sensitizations using immunoblotting This is the first study presenting the results of a self-prepared cattle allergen mix that was designed to represent the full spectrum of cattle allergens present in a typical agricultural workplace. The self-prepared AG-014699 supplier cattle allergen mix encompasses the spectrum of proteins in a molecular range from lower than 6.5 kDa up to 66 kDa and greater (at approximately 11, 20, 22, 25, 55, 62 and 66 kDa as well as between 25 to 30 and lower than 6.5 kDa), that was obtained by SDS-PAGE-separation Inflammation related inhibitor of extracts from the hair of various cattle races (Fig. 1). The allergenic potential of the extracts concerning the different bands was verified using the sera of various confirmed cattle-allergic patients as previously described (Heutelbeck et al. 2009). Fig. 1 SDS-PAGE of the self-prepared cattle allergen mix: prepared extracts were separated using SDS-PAGE. The following marker and samples were applied: lane 1 molecular weight marker (molecular weights given in kDa), lane 2 self-prepared cattle allergen mix In this study, immunoblot investigations with a self-prepared cattle allergen mix were performed
on 37 claw trimmers of whom 27 reported work-related symptoms and 20 showed a cattle sensitization with at least one commercial test. Positive specific reactions were detected in 94.6% of the samples (n = 35). Typical results with special attention to different sensitization status, given in from the amount of specific IgE (kU/l) antibodies against cattle with the commercial cattle allergen tests of Hycor and Phadia, are shown in Fig. 2a–d.
In most of our immunoblot experiments, we observed distinct bands at a molecular weight of about 16 kDa and rarely in the range of about 20 kDa, reflecting the major component bos d 2. Sporadically, specific reactions were seen at a molecular weight of about 6 kDa, about 29 kDa and in the range between 14.3 and 21 kDa, between 21 and 29 kDa, as well as in the range greater than 45 kDa, The negative controls of all sera of non-symptomatic non-exposed individuals and non-sensitized, non-symptomatic claw trimmers showed unspecific staining in the molecular range between 45 and 67 kDa (examples are shown in Fig. 2e, f). Fig. 2 Immunoblot of the self-prepared cattle allergen mix: proteins were separated by SDS-PAGE and transferred to PVDF membranes. These were developed with serum of symptomatic claw trimmers with different sensitization status, given in the amount of specific IgE (kU/l) against cattle allergen using the commercial tests of Hycor and Phadia (a–d); a 0.11 kU/l (Hycor) and 0.05 kU/l (Phadia), b 0.